Floor or ground surfaces of ramp runs shall comply with 302.
The ada discusses ground and floor surfaces in section 4 5.
302 1 floor or ground surfaces.
General 4 5 1 guidance on the 2010 ada standards for accessible design 1 302 1 floor or ground surfaces.
4 5 1 general ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors walks ramps stairs and curb ramps shall be stable firm slip resistant and shall comply with 4 5.
405 4 floor or ground surfaces.
Swinging door and gate surfaces within 10 inches 255 mm of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate.
4 5 ground and floor surfaces.
Parts creating horizontal or vertical joints in these surfaces shall be within 1 16 inch 1 6 mm of the same plane as the other.
Ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors walks ramps stairs and curb ramps shall be stable firm slip resistant and shall comply with 4 5.
Both section 4 5 1 of the 1991 standards and section 302 2 of the 2010 standards require that floor or ground surfaces along accessible routes and in accessible rooms and spaces be stable firm slip resistant and comply with either section 4 5 in the case of the 1991 standards or section 302 in the case of the 2010 standards.
The clear width of a ramp run and where handrails are provided the clear width between handrails shall be 36 inches 915 mm minimum.
Any occupiable floor less than one story above or below grade with direct.
Changes in level other than the running slope and cross slope are not permitted on ramp runs.
Guide to the ada standards 1 firmness stability and slip resistance 302 1 technical bulletin.
2013 forest service outdoor recreation accessibility.
Ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors walks ramps stairs and curb ramps shall be stable firm slip resistant and shall comply with 4 5.
Ada standards for accessible design 28 cfr part 36.
4 5 ground and floor surfaces.
Justice under the americans with disabilities act of 1990.
Ground and floor surfaces 1 technical bulletin.
4 5 2 changes in level.
4 5 ground and floor surfaces.
Ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors walks ramps stairs and curb ramps shall be stable firm slip resistant and shall comply with 4 5.
The ada discusses ground and floor surfaces in section 4 5 where they say in general that.
New construction and 4 1 6 parking and passenger loading zones.
4 1 2 accessible sites and exte rior facilities.
Access aisle of at least 60 inch width must be level 1 50 maximum slope in all directions be the same length as the adjacent parking space s it.
Feature built in or applied to walking surfaces or other elements to warn visually impaired people of hazards on a circulation path.